struct fins_cycletime_tp;

Fields

Field Type Description
avg uint32_t The average cycle time over the last eight cycles of the PLC. The time is expressed in units of 0.1 msec.
max uint32_t The maximum cycle time of the PLC since the last cycle time reset. The time is expressed in units of 0.1 msec.
min uint32_t The minimum cycle time of the PLC since the last cycle time reset. The time is expressed in units of 0.1 msec.

Description

The structure fins_cycletime_tp is used by the function finslib_cycle_time_read() to store the minimum, average and maximum cycle times of the PLC. The average cycle time is calculated over the last eight cycles. Note that the values are in 0.1 millisecond increments.